{"product":{"productId":"agid.14734","price":546.58,"name":"Stops adjustable, stainless steel with status sensor"},"currency":"PLN"}
Materiał
Screw and plunger stainless steel 1.4301.
Guide bush stainless steel 1.4112.
Status sensor stainless steel.
Wersja
Screw, plunger, guide bush and status sensor bright.
Wyświetl więcej
Wyświetl mniej
Opis
Opis produktu
In addition to their mechanical function as a support element, adjustable stops with status sensor are used to detect whether a component is in contact with the stop or not.
The sensor recognises whether the plunger is retracted or extended and enables this status information to be electronically processed.
The sensor recognises whether the plunger is retracted or extended and enables this status information to be electronically processed.
Materiał
Screw and plunger stainless steel 1.4301.
Guide bush stainless steel 1.4112.
Status sensor stainless steel.
Wersja
Screw, plunger, guide bush and status sensor bright.
Wskazówka
The assured switch distance is achieved when the plunger is flush with the stop face of the guide bush. The sensor is supplied unassembled.
Installation recommendation: Glue in using e.g. Loctite 638.
Cable length: 0.3 metre.
Important: Screw the sensor in as far as it will go!
Installation recommendation: Glue in using e.g. Loctite 638.
Cable length: 0.3 metre.
Important: Screw the sensor in as far as it will go!
Dane techniczne
Inductive sensor:
Output relay: PNP normally open (NO)
Operating voltage: 10 - 30 V DC
Operating current: 100 mA
Switch gap: 0.8 mm
Switching frequency: 5000 Hz
Short-circuit proof: yes
Reverse polarity protected: yes
IP rating: IP 67
Connection type: 0.3 m cable, PUR, with plug
Temperature range: -25° C - +70°C
Approvals: CE, c-UL-us, UKCA, WEEE
Output relay: PNP normally open (NO)
Operating voltage: 10 - 30 V DC
Operating current: 100 mA
Switch gap: 0.8 mm
Switching frequency: 5000 Hz
Short-circuit proof: yes
Reverse polarity protected: yes
IP rating: IP 67
Connection type: 0.3 m cable, PUR, with plug
Temperature range: -25° C - +70°C
Approvals: CE, c-UL-us, UKCA, WEEE
Zastosowanie
Stops with status sensors enable status-dependent process control. It can be ensured that a workpiece or moving component is in the desired location before further steps follow.
Montaż
The status sensor must be screwed in as far as it will go.
It is recommended that this be glued in e.g. using Loctite 638.
It is recommended that this be glued in e.g. using Loctite 638.
Bezpieczeństwo
Stops with status sensors are not suitable for safeguarding persons.
Bezpieczeństwo
End position feedback stops are not suitable for personal protection.
Wskazówka dotycząca planu
1) Screw
2) Plunger
3) Guide bush
4) Status sensor
5) LED indicator
BN = Brown
BK = Black
BU = Blue
2) Plunger
3) Guide bush
4) Status sensor
5) LED indicator
BN = Brown
BK = Black
BU = Blue