Description

Product description
The wear of the embossing jaws can be checked with the test blocks.
Material
Steel.
Version
Hardened.
Note
Step 1: Position the positioner and embossing slide with a spacing of ca. 15 mm
Step 2: Set the test blocks (1) marked ‘l/r’ (with the additional grooves) to the left and right of the embossing jaws so that they are flush with the outer edge.
Step 3: Use the knurled screw (fine adjustment) to close the embossing jaws until the test blocks are clamped by hand.
Step 4: Try to place the test block (2), marked ‘m’, between the teeth.
- If the test block does not fit between the teeth of the embossing jaws, everything is fine.
- If the test block fits between the teeth of the embossing jaws, the jaws must be reworked or replaced.

The embossing jaws can be reworked to a thickness of up to 11.5 mm (measured from the highest tooth). That amounts to 6 reworks.
If a tooth has broken off, the number of possible reworkings is reduced.